Back to Properties

P-0092

Kilargo

Active
15 Wentworth Place Banyo Queensland 4013Kilargo

Assets

55

Tasks

50

Defect Quotes

15

Building Type

—

Assets (55)

RefTypeLabelLocationCompliance
01510 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableMaintenance (loose)Unknown
00515 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingWorkshop - South Row 2 from office endCompliant
00415 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingWorkshop - South Row 1 from office endNon-compliant
00315 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingTop of stairsCompliant
00215 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingSouth end outside toiletsCompliant
00115 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingNorth end of officeCompliant
00611 - Fire Blankets11 - Fire BlanketsShed behind Acoustic LabNon-compliant
00504 - Fire Hydrant System04 - Fire Hydrant SystemFront gateCompliant
00404 - Fire Hydrant System04 - Fire Hydrant SystemNorth side of carpark (approx. centre)Compliant
00309 - Fire Hose Reels09 - Fire Hose ReelsCentre of factory, rear wallCompliant
00209 - Fire Hose Reels09 - Fire Hose ReelsFabricationCompliant
00109 - Fire Hose Reels09 - Fire Hose ReelsDispatch AreaCompliant
00106 - Fire Detection Systems - Panels06 - Fire Detection Systems - PanelsReceptionNon-compliant
02010 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableWash bayUnknown
01810 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableWelding bayUnknown
02711 - Fire Blankets11 - Fire BlanketsLunch roomCompliant
02610 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableCentre of workshop adj Hosereel 3Compliant
02511 - Fire Blankets11 - Fire BlanketsGround Office KitchenCompliant
02410 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableShed behind acoustic labCompliant
02310 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableMezzanine storage officeCompliant
02210 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableBottom of loading stairsCompliant
02110 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableIFDCompliant
01910 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableSilicon roomCompliant
01710 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableIFDCompliant
01610 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableFabrication SW cornerCompliant
01410 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableMaintenanceCompliant
01310 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableAcoustic labCompliant
01210 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableExit at centre of North wallCompliant
01110 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableProduction officeCompliant
01010 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableGround floor open officeCompliant
00910 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableUpstairs officeCompliant
00810 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableGround floor office near toiletsCompliant
00710 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableReceptionCompliant
01315 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingWorkshop - North Row 5 from office endCompliant
01215 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingWorkshop - North Row 4 from office endCompliant
01115 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingWorkshop - North Row 3 from office endCompliant
01015 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingWorkshop - North Row 2 from office endCompliant
00915 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingWorkshop - North Row 1 from office endCompliant
00815 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingWorkshop - South Row 5 from office endCompliant
00715 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingWorkshop - South Row 4 from office endCompliant
00615 - Emergency Escape Lighting and Exit Signs for Building15 - Emergency Escape Lighting and Exit Signs for BuildingWorkshop - South Row 3 from office endCompliant
02810 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableAdjacent to last roller door on right hand sideCompliant
02910 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableWelding bayCompliant
03011 - Fire Blankets11 - Fire BlanketsUpstairs KitchenetteCompliant
00106 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)06 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)Ground floor corridor return air grillCompliant
00206 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)06 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)Zone 1 - fire panelCompliant
00306 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)06 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)Zone 2 - factory southCompliant
00406 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)06 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)Zone 2 - factory southNon-compliant
00506 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)06 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)Zone 2 - factory southCompliant
00606 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)06 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)Zone 2 - factory southNon-compliant
00706 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)06 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)Zone 3 - factory northNon-compliant
00806 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)06 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)Zone 3 - factory northNon-compliant
00906 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)06 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)Zone 3 - factory northCompliant
01006 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)06 - Fire Detection Devices (MCP, Detector, strobe, Flow Switch)Zone 3 - factory northNon-compliant
03110 - Fire Extinguishers - Portable10 - Fire Extinguishers - PortableLevel 1 R&D RoomCompliant

Tasks (50)

RefTaskStatusDue
T-20495PM2026/09 Default Service Group (P-0092) Ready15 Sept 2026
T-19968Fixed: Kilargo (Fixed)Complete15 Aug 2026
T-19302PM2026/08 Default Service Group (P-0092) Complete15 Aug 2026
T-19078Fixed: Kilargo (Fixed)Complete15 July 2026
T-18977Q-1122 WorksComplete—
T-18780PM2026/07 Default Service Group (P-0092) Complete15 July 2026
T-18582Fixed: Kilargo (Fixed)Complete15 June 2026
T-18547Q-1123 WorksReady—
T-18297PM2026/06 Default Service Group (P-0092) Complete15 June 2026
T-18273PM2026/06 Default Service Group (P-0092) Complete15 June 2026
T-18262PM2026/06 Default Service Group (P-0092) Complete15 June 2026
T-18258PM2026/06 Default Service Group (P-0092) Complete15 June 2026
T-17923Fixed: Kilargo (Fixed)Complete15 May 2026
T-17408PM2026/05 Default Service Group (P-0092) Complete15 May 2026
T-17064Fixed: Kilargo (Fixed)Complete15 Apr 2026
T-16588PM2026/04 Default Service Group (P-0092) Complete15 Apr 2026
T-15711Fixed: Kilargo (Fixed)Complete15 Mar 2026
T-15412Fire Extinguisher Defects Quotation - December 2025 (Quote Q-0929)Complete—
T-15100PM2026/03 Default Service Group (P-0092) Complete15 Mar 2026
T-14885Fire Detection Defect Repairs Quotation - January 2026 (Quote Q-0954)Complete—
T-14787Fixed: Kilargo (Fixed)Complete15 Feb 2026
T-14237PM2026/02 Default Service Group (P-0092) Complete15 Feb 2026
T-13765Fixed: Kilargo (Fixed)Complete15 Jan 2026
T-13111PM2026/01 Default Service Group (P-0092) Complete15 Jan 2026
T-12808Fixed: Kilargo (Fixed)Complete15 Dec 2025
T-12393PM2025/12 Default Service Group (P-0092) Complete15 Dec 2025
T-12392PM2025/12 Default Service Group (P-0092) Complete15 Dec 2025
T-12391PM2025/12 Default Service Group (P-0092) Complete15 Dec 2025
T-12390PM2025/12 Default Service Group (P-0092) Complete15 Dec 2025
T-12147Fixed: Kilargo (Fixed)Complete15 Nov 2025
T-11429PM2025/11 Default Service Group (P-0092) Complete15 Nov 2025
T-11191Fixed: Kilargo (Fixed)Complete15 Oct 2025
T-10407PM2025/10 Default Service Group (P-0092) Complete15 Oct 2025
T-10018Fixed: Kilargo (Fixed)Complete15 Sept 2025
T-09421PM2025/09 Default Service Group (P-0092) Complete15 Sept 2025
T-09190Fixed: Kilargo (Fixed)Complete15 Aug 2025
T-08764PM2025/08 Default Service Group (P-0092) Complete15 Aug 2025
T-08531Fixed: Kilargo (Fixed)Complete15 July 2025
T-08350Kilargo - Quotation for 5-Yearly Fire Hydrant System Inspection.Test - June 2025 (Quote Q-0698)Complete—
T-08317kilargo - Fire Hose Reel Replacement - June 2025 (Quote Q-0754)Complete—
T-08194PM2025/07 Default Service Group (P-0092) Complete15 July 2025
T-08070Fixed: Kilargo (Fixed)Complete15 June 2025
T-07652PM2025/06 Default Service Group (P-0092) Complete15 June 2025
T-07639PM2025/06 Default Service Group (P-0092) Complete15 June 2025
T-07635PM2025/06 Default Service Group (P-0092) Complete15 June 2025
T-07630PM2025/06 Default Service Group (P-0092) Complete15 June 2025
T-07629PM2025/06 Default Service Group (P-0092) Complete15 June 2025
T-07615PM2025/06 Default Service Group (P-0092) Complete15 June 2025
T-07581PM2025/06 Default Service Group (P-0092) Complete15 June 2025
T-07580PM2025/06 Default Service Group (P-0092) Complete15 June 2025

Defect Quotes (15)

RefSeverityStatusRaisedDue
Q-1147—Submitted30 July 202630 Aug 2026
Q-1123—Actioned8 June 20268 July 2026
Q-1122—Actioned8 June 20268 July 2026
Q-0954—Actioned29 Jan 202628 Feb 2026
Q-0929—Actioned10 Dec 202528 Feb 2026
Q-0823—Voided23 July 202530 Nov 2025
Q-0822—Voided23 July 202530 Nov 2025
Q-0754—Actioned30 June 202530 July 2025
Q-0753—Voided30 June 202530 July 2025
Q-0698—Actioned2 June 20252 July 2025
Q-0584—Actioned30 Jan 20251 Mar 2025
Q-0547—Voided11 Dec 202411 Jan 2025
Q-0504—Voided4 Oct 20243 Nov 2024
Q-0364—Actioned22 July 202421 Aug 2024
Q-0263—Actioned24 Apr 202424 May 2024