Scope of works
**Leading Fire Services are pleased to submit for your consideration our proposal for conducting the 10-Yearly Fire Tank inspection and Diver clean.** **As Requested, our quotation is for the following;** **INCLUSIONS: 2 x Fire Tanks - 10 Yearly Inspection & Service (Dive)** * Works carried out in general accordance with relevant AS1851, 3500. * Preliminary site assessment & safety setup. * Establishment of exclusions zones and permit to work documentation. * ADAS certified dive team to access and clean tank with head pressure OR pump to siphon suction vacuum including: - Removal of sharps - Removal of sludge * Supply of full inspection internally/ externally with report including; - High-resolution video and photographic documentation on works completed. * Commentary on structural condition and recommendations. - Photos/videos of interior. *Submission of reporting as per AS1851. The inspection results will form part of the maintenance report or certification issued by Leading Fire Services. * Insurances, SWMS, program and permits * Delivery to site Spring Creek. * Qualified personnel which hold confined space rescue and working at heights rescue, standard PPE * Hire of calibrated gas detectors and emergency extraction system (tripod, harness, ropes etc) * Our Divers will be utilising full safety systems in place to protect against tank suction events, however, as another layer of additional Safety, both the Fire Electric and Diesel Fire Pumps will be isolated for these works and system monitored by LFS Staff and in contact with PFM and Master Control - SQCC. IF an event occurs, LFS will take immediate charge of the event, recover Divers from the relevant Tank, and restore Fire Pumps for Normal operation. **Please Note: If approved, mobilisation can be arranged for these works within 10-14 days.** **The Building Fire Safety Regulation 2008, Part 5 Prescribed fire safety installations, Division 3 Obligations of occupiers, 54 Maintenance of prescribed fire safety installations Part 4 states that:** **(4) The occupier of the building must ensure the repair is carried out or the corrective action is taken no later than 1 month after the maintenance of the installation was carried out, unless the occupier has a reasonable excuse.** ***Examples of a reasonable excuse— • No appropriately qualified person was available to attend the occupier’s premises to carry out the repair or take the corrective action because of the remoteness of the building’s location. • The repair or corrective action was not able to be finished because of the complexity of the work involved or delay in obtaining parts required for the repair or corrective action.*** Unless specifically noted above, or stated/included within our Scope of Works, the following inclusions, Exclusions, Notes and Conditions will apply: INCLUSIONS: • Labour during Leading Fire Services normal working hours (7.00am to 4.00pm Mon to Fri, excluding Public Holidays). EXCLUSIONS: • Any additional materials or parts not listed in this quote including diesel, batteries, tubes and the like. • Work outside of Leading Fire Services normal working hours (as nominated above). • Scaffolding, Elevated Work Platforms or any High Access Equipment over and above standard 1.8m Step. • Patching, Painting, Core Holes, Fire Penetrations, Fire Sealing, Chasing, Rendering or Cleaning – touch up painting of any doors or frames. • Any re-keying to match original pre-existing key setup of locksets that have been replaced or altered. • Access to Energex locked rooms. • If water isolation for repairs is not successful, costs will apply for pipe freeze. NOTES & CONDITIONS: • Leading Fire Services standard trading terms apply. A copy of our trading terms can be provided on request. • Leading Fire Services reserve the right to vary our pricing where additional WH&S measures are implemented, not limited to but including: new or modified induction processes, additional police or security checks and assistance with third party auditing. • Where recommendations are made we have allowed to rectify, this price is only valid if accepted with the rest of the quote. • Uninterrupted and continuous site access is required. Delays will incur additional costs at our standard hourly rates. • This quote is valid for a period of 30 days from date of quotation, after which time price adjustments may be required. • The customer is fully responsible to provide access, security clearances and keys on site at time of all routine inspections, call outs in normal working hours and call outs outside working hours and quoted works. All inductions that are beyond thirty minutes duration, will be charged at our normal hourly rate. Parking facilities will be provided and if not, all costs associated will be on charged to the client. • Our pricing has been calculated on the proviso that the full scope of works will be approved and carried out at the same time. Multiple site visits (other than those already expected and allowed for) or variations to our original scope of works, may attract further costs. • In accordance with AS 1851 – 2012 during a hydrostatic test the hydrant system pipe work is pressurized to 1.5 times the systems working pressure or the required design standards. If any unknown system defects are present, a failure of the hydrant system pipe work may occur resulting in damage to building, plant, equipment, facility, or part thereof. Leading Fire Services Pty Ltd will be held harmless and accept no responsibility for any damage to building, plant, equipment, facility, or part thereof, as a result of any failure of the fitted Fire Hydrant System during any authorized pre-arranged Hydrostatic Test and Hydrant Flow test. • Please note that for any works conducted, if any other Companies working on these tanks after our works have been completed will void any applicable warranty on works conducted. • If any variations are required, rates are as follows; LFS Personnel - Charged at standard Contract rates, $220.00 + G.S.T. for any additional Accredited Diver per hour, $160.00 for Diver Supervisors(s) per hour, and $135.00 for additional Labourers surrounding the above listed tank works. • Firstly, we will attempt to utilise the tanks drain, with a head pressure vacuum suction, which discharges to the adjacent stormwater swale/ legal point of discharge as that's where the discharge has been designed to flow. If for some reason the valve is faulty, we will have a suction pipe that we can hang over the roof and side of the tank. We will utilise a siphon effect with a pump and use that suction to vacuum any sediment/ sludge from the base of the tank. If the client is happy for water to dump off the side of the tank that is great, if not we have no allowance for temporary diversion pipework to the nearest stormwater pit and would require PFM assistance to redirect to the suitable location. We would like to thank you for considering Leading Fire Services proposal, and we look forward to working with you should our quote be accepted. If you have any queries or require further information, please do not hesitate in contacting us.
Description
SQCC - Fire Tank 10-Yearly Inspection and Diver Tank Clean - November 2025